tau1-v.tlan


%%%%%%%%%%%%%%%%%%%%
%% IPP 1 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	0
AT	1	CHQPULS,AD1L,AD2R,STFIR
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +++
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -----
AT	964 	PHA180 		% +++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +++
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -----
AT	4198 	BRX5OFF 		% +++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 1 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	15600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +++
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -----
AT	964 	PHA180 		% +++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +++
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -----
AT	4198 	BRX5OFF 		% +++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 2 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	31200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++++
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +++
AT	748 	PHA0 		% ----
AT	1036 	PHA180 		% ++ ++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++++
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +++
AT	3982 	BRX5 		% ----
AT	4270 	BRX5OFF 		% ++ ++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 2 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	46800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++++
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +++
AT	748 	PHA0 		% ----
AT	1036 	PHA180 		% ++ ++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++++
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +++
AT	3982 	BRX5 		% ----
AT	4270 	BRX5OFF 		% ++ ++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 3 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	62400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% ++
AT	460 	PHA0 		% --
AT	604 	PHA180 		% +++
AT	820 	PHA0 		% -
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -- --
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% ++
AT	3694 	BRX5 		% --
AT	3838 	BRX5OFF 		% +++
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -- --
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 3 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	78000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% ++
AT	460 	PHA0 		% --
AT	604 	PHA180 		% +++
AT	820 	PHA0 		% -
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -- --
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% ++
AT	3694 	BRX5 		% --
AT	3838 	BRX5OFF 		% +++
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -- --
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 4 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	93600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% ++
AT	460 	PHA0 		% ----
AT	748 	PHA180 		% +
AT	820 	PHA0 		% -
AT	892 	PHA180 		% +
AT	964 	PHA0 		% ---
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% ++
AT	3694 	BRX5 		% ----
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% ---
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 4 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	109200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% ++
AT	460 	PHA0 		% ----
AT	748 	PHA180 		% +
AT	820 	PHA0 		% -
AT	892 	PHA180 		% +
AT	964 	PHA0 		% ---
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% ++
AT	3694 	BRX5 		% ----
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% ---
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 5 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	124800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +
AT	460 	PHA0 		% ---
AT	676 	PHA180 		% ++++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% ++ ++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% ---
AT	3910 	BRX5OFF 		% ++++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% ++ ++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 5 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	140400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +
AT	460 	PHA0 		% ---
AT	676 	PHA180 		% ++++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% ++ ++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% ---
AT	3910 	BRX5OFF 		% ++++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% ++ ++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 6 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	156000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +
AT	460 	PHA0 		% --
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -
AT	748 	PHA180 		% ++++++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% --
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% ++++++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 6 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	171600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +
AT	460 	PHA0 		% --
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -
AT	748 	PHA180 		% ++++++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% --
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% ++++++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 7 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	187200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ---
AT	388 	PHA180 		% +
AT	460 	PHA0 		% -
AT	532 	PHA180 		% ++
AT	676 	PHA0 		% --
AT	820 	PHA180 		% +
AT	892 	PHA0 		% ----
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ---
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% ++
AT	3910 	BRX5 		% --
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% ----
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 7 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	202800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ---
AT	388 	PHA180 		% +
AT	460 	PHA0 		% -
AT	532 	PHA180 		% ++
AT	676 	PHA0 		% --
AT	820 	PHA180 		% +
AT	892 	PHA0 		% ----
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ---
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% ++
AT	3910 	BRX5 		% --
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% ----
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 8 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	218400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% --
AT	388 	PHA180 		% +
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +
AT	748 	PHA0 		% -
AT	820 	PHA180 		% +
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -- --
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% --
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -- --
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 8 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	234000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% --
AT	388 	PHA180 		% +
AT	460 	PHA0 		% -
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +
AT	748 	PHA0 		% -
AT	820 	PHA180 		% +
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -- --
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% --
AT	3622 	BRX5OFF 		% +
AT	3694 	BRX5 		% -
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -- --
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 9 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	249600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++
AT	388 	PHA0 		% -----
AT	748 	PHA180 		% ++
AT	892 	PHA0 		% ---- ----
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++
AT	3622 	BRX5 		% -----
AT	3982 	BRX5OFF 		% ++
AT	4126 	BRX5 		% ---- ----
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 9 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	265200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++
AT	388 	PHA0 		% -----
AT	748 	PHA180 		% ++
AT	892 	PHA0 		% ---- ----
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++
AT	3622 	BRX5 		% -----
AT	3982 	BRX5OFF 		% ++
AT	4126 	BRX5 		% ---- ----
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 10 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	280800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++
AT	388 	PHA0 		% ---
AT	604 	PHA180 		% ++++
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% --
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++
AT	3622 	BRX5 		% ---
AT	3838 	BRX5OFF 		% ++++
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% --
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 10 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	296400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++
AT	388 	PHA0 		% ---
AT	604 	PHA180 		% ++++
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% --
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++
AT	3622 	BRX5 		% ---
AT	3838 	BRX5OFF 		% ++++
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% --
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 11 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	312000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +
AT	388 	PHA0 		% --
AT	532 	PHA180 		% +++
AT	748 	PHA0 		% -
AT	820 	PHA180 		% ++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% ++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% --
AT	3766 	BRX5OFF 		% +++
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% ++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% ++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 11 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	327600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +
AT	388 	PHA0 		% --
AT	532 	PHA180 		% +++
AT	748 	PHA0 		% -
AT	820 	PHA180 		% ++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% ++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% --
AT	3766 	BRX5OFF 		% +++
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% ++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% ++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 12 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	343200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% +
AT	388 	PHA0 		% --
AT	532 	PHA180 		% +
AT	604 	PHA0 		% ---
AT	820 	PHA180 		% +++++ +++++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% --
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% ---
AT	4054 	BRX5OFF 		% +++++ +++++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 12 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	358800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% +
AT	388 	PHA0 		% --
AT	532 	PHA180 		% +
AT	604 	PHA0 		% ---
AT	820 	PHA180 		% +++++ +++++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% --
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% ---
AT	4054 	BRX5OFF 		% +++++ +++++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 13 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	374400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% ---
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +
AT	748 	PHA0 		% --
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% --
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% ---
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% --
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% --
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 13 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	390000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% ---
AT	532 	PHA180 		% +
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +
AT	748 	PHA0 		% --
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% --
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% ---
AT	3766 	BRX5OFF 		% +
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% --
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% --
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 14 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	405600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% ---
AT	532 	PHA180 		% ++
AT	676 	PHA0 		% ---
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --- ---
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% ---
AT	3766 	BRX5OFF 		% ++
AT	3910 	BRX5 		% ---
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --- ---
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 14 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	421200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% ---
AT	532 	PHA180 		% ++
AT	676 	PHA0 		% ---
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --- ---
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% ---
AT	3766 	BRX5OFF 		% ++
AT	3910 	BRX5 		% ---
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --- ---
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 15 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	436800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ------
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -
AT	748 	PHA180 		% +
AT	820 	PHA0 		% --
AT	964 	PHA180 		% +++ +++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ------
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% --
AT	4198 	BRX5OFF 		% +++ +++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 15 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	452400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ------
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -
AT	748 	PHA180 		% +
AT	820 	PHA0 		% --
AT	964 	PHA180 		% +++ +++
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ------
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% --
AT	4198 	BRX5OFF 		% +++ +++
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 16 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	468000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% ------
AT	676 	PHA180 		% ++
AT	820 	PHA0 		% ---
AT	1036 	PHA180 		% ++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% ------
AT	3910 	BRX5OFF 		% ++
AT	4054 	BRX5 		% ---
AT	4270 	BRX5OFF 		% ++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 16 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	483600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% ------
AT	676 	PHA180 		% ++
AT	820 	PHA0 		% ---
AT	1036 	PHA180 		% ++
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% ------
AT	3910 	BRX5OFF 		% ++
AT	4054 	BRX5 		% ---
AT	4270 	BRX5OFF 		% ++
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 17 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	499200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++++
AT	532 	PHA0 		% ----
AT	820 	PHA180 		% +
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++++
AT	3766 	BRX5 		% ----
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 17 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	514800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++++
AT	532 	PHA0 		% ----
AT	820 	PHA180 		% +
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++++
AT	3766 	BRX5 		% ----
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 18 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	530400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++++
AT	532 	PHA0 		% -
AT	604 	PHA180 		% ++
AT	748 	PHA0 		% -
AT	820 	PHA180 		% +
AT	892 	PHA0 		% ---
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++++
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% ++
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% ---
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 18 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	546000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++++
AT	532 	PHA0 		% -
AT	604 	PHA180 		% ++
AT	748 	PHA0 		% -
AT	820 	PHA180 		% +
AT	892 	PHA0 		% ---
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++++
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% ++
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% +
AT	4126 	BRX5 		% ---
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 19 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	561600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +++++++++++
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +++++++++++
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 19 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	577200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +++++++++++
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +++++++++++
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 20 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	592800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% ++++
AT	604 	PHA0 		% --
AT	748 	PHA180 		% +++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% ++++
AT	3838 	BRX5 		% --
AT	3982 	BRX5OFF 		% +++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 20 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	608400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% ++++
AT	604 	PHA0 		% --
AT	748 	PHA180 		% +++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% ++++
AT	3838 	BRX5 		% --
AT	3982 	BRX5OFF 		% +++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 21 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	624000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +++
AT	604 	PHA0 		% -
AT	676 	PHA180 		% ++
AT	820 	PHA0 		% -
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +++
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% ++
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 21 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	639600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% -
AT	388 	PHA180 		% +++
AT	604 	PHA0 		% -
AT	676 	PHA180 		% ++
AT	820 	PHA0 		% -
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% +++
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% ++
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 22 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	655200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% -
AT	388 	PHA180 		% ++++
AT	676 	PHA0 		% -
AT	748 	PHA180 		% +
AT	820 	PHA0 		% -
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% ++++
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 22 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	670800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% -
AT	388 	PHA180 		% ++++
AT	676 	PHA0 		% -
AT	748 	PHA180 		% +
AT	820 	PHA0 		% -
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% -
AT	3622 	BRX5OFF 		% ++++
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% -
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 23 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	686400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ---
AT	388 	PHA180 		% ++
AT	532 	PHA0 		% -
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -----
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ---
AT	3622 	BRX5OFF 		% ++
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -----
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 23 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	702000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ---
AT	388 	PHA180 		% ++
AT	532 	PHA0 		% -
AT	604 	PHA180 		% +
AT	676 	PHA0 		% -----
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ---
AT	3622 	BRX5OFF 		% ++
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% -----
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 24 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	717600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% --
AT	388 	PHA180 		% ++
AT	532 	PHA0 		% --
AT	676 	PHA180 		% +
AT	748 	PHA0 		% ---
AT	964 	PHA180 		% ++
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% --
AT	3622 	BRX5OFF 		% ++
AT	3766 	BRX5 		% --
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% ---
AT	4198 	BRX5OFF 		% ++
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 24 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	733200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% --
AT	388 	PHA180 		% ++
AT	532 	PHA0 		% --
AT	676 	PHA180 		% +
AT	748 	PHA0 		% ---
AT	964 	PHA180 		% ++
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% --
AT	3622 	BRX5OFF 		% ++
AT	3766 	BRX5 		% --
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% ---
AT	4198 	BRX5OFF 		% ++
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 25 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	748800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++
AT	388 	PHA0 		% -
AT	460 	PHA180 		% ++
AT	604 	PHA0 		% --
AT	748 	PHA180 		% +
AT	820 	PHA0 		% ---
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% ++
AT	3838 	BRX5 		% --
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% ---
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 25 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	764400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% ++
AT	388 	PHA0 		% -
AT	460 	PHA180 		% ++
AT	604 	PHA0 		% --
AT	748 	PHA180 		% +
AT	820 	PHA0 		% ---
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% ++
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% ++
AT	3838 	BRX5 		% --
AT	3982 	BRX5OFF 		% +
AT	4054 	BRX5 		% ---
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 26 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	780000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +++++
AT	820 	PHA0 		% --
AT	964 	PHA180 		% ++
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +++++
AT	4054 	BRX5 		% --
AT	4198 	BRX5OFF 		% ++
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 26 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	795600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++++
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +++++
AT	820 	PHA0 		% --
AT	964 	PHA180 		% ++
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++++
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +++++
AT	4054 	BRX5 		% --
AT	4198 	BRX5OFF 		% ++
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 27 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	811200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -
AT	604 	PHA180 		% ++
AT	748 	PHA0 		% --
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% ++
AT	3982 	BRX5 		% --
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 27 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	826800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% --
AT	316 	PHA180 		% +
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -
AT	604 	PHA180 		% ++
AT	748 	PHA0 		% --
AT	892 	PHA180 		% +
AT	964 	PHA0 		% --
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% --
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% ++
AT	3982 	BRX5 		% --
AT	4126 	BRX5OFF 		% +
AT	4198 	BRX5 		% --
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 28 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	842400
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% +
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -----
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -----
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 28 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	858000
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% -
AT	316 	PHA180 		% +
AT	388 	PHA0 		% -
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -----
AT	892 	PHA180 		% ++
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% -
AT	3550 	BRX5OFF 		% +
AT	3622 	BRX5 		% -
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -----
AT	4126 	BRX5OFF 		% ++
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 29 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	873600
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% --
AT	460 	PHA180 		% +
AT	532 	PHA0 		% --
AT	676 	PHA180 		% +
AT	748 	PHA0 		% -
AT	820 	PHA180 		% ++++
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% --
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% --
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% ++++
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 29 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	889200
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% -
AT	244 	PHA180 		% +
AT	316 	PHA0 		% --
AT	460 	PHA180 		% +
AT	532 	PHA0 		% --
AT	676 	PHA180 		% +
AT	748 	PHA0 		% -
AT	820 	PHA180 		% ++++
AT	1108 	PHA0 		% - -
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% -
AT	3478 	BRX5OFF 		% +
AT	3550 	BRX5 		% --
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% --
AT	3910 	BRX5OFF 		% +
AT	3982 	BRX5 		% -
AT	4054 	BRX5OFF 		% ++++
AT	4342 	BRX5 		% - -
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 30 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	904800
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% --
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -
AT	604 	PHA180 		% +
AT	676 	PHA0 		% --
AT	820 	PHA180 		% ++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% --
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% --
AT	4054 	BRX5OFF 		% ++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 30 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	920400
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +++
AT	316 	PHA0 		% --
AT	460 	PHA180 		% +
AT	532 	PHA0 		% -
AT	604 	PHA180 		% +
AT	676 	PHA0 		% --
AT	820 	PHA180 		% ++
AT	964 	PHA0 		% -
AT	1036 	PHA180 		% +
AT	1108 	PHA0 		% -
AT	1180 	PHA180 		% + 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +++
AT	3550 	BRX5 		% --
AT	3694 	BRX5OFF 		% +
AT	3766 	BRX5 		% -
AT	3838 	BRX5OFF 		% +
AT	3910 	BRX5 		% --
AT	4054 	BRX5OFF 		% ++
AT	4198 	BRX5 		% -
AT	4270 	BRX5OFF 		% +
AT	4342 	BRX5 		% -
AT	4414 	BRX5OFF 		% + 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 31 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	936000
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ----
AT	460 	PHA180 		% +++
AT	676 	PHA0 		% -
AT	748 	PHA180 		% ++
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ----
AT	3694 	BRX5OFF 		% +++
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% ++
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 31 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	951600
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% +
AT	172 	PHA0 		% ----
AT	460 	PHA180 		% +++
AT	676 	PHA0 		% -
AT	748 	PHA180 		% ++
AT	892 	PHA0 		% -
AT	964 	PHA180 		% +
AT	1036 	PHA0 		% -
AT	1108 	PHA180 		% +
AT	1180 	PHA0 		% - 
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% +
AT	3406 	BRX5 		% ----
AT	3694 	BRX5OFF 		% +++
AT	3910 	BRX5 		% -
AT	3982 	BRX5OFF 		% ++
AT	4126 	BRX5 		% -
AT	4198 	BRX5OFF 		% +
AT	4270 	BRX5 		% -
AT	4342 	BRX5OFF 		% +
AT	4414 	BRX5 		% - 
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 32 SUBCYCLE 1 
%%%%%%%%%%%%%%%%%%%%
SETTCR	967200
AT	9	NCOSEL1
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% ---
AT	460 	PHA180 		% ++
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +++
AT	892 	PHA0 		% ---
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% ---
AT	3694 	BRX5OFF 		% ++
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +++
AT	4126 	BRX5 		% ---
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 32 SUBCYCLE 2 
%%%%%%%%%%%%%%%%%%%%
SETTCR	982800
AT	9	NCOSEL2
AT	10	RXPROT,LOPROT
AT	55	BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT	100 	RFON,PHA180 		% ++
AT	244 	PHA0 		% ---
AT	460 	PHA180 		% ++
AT	604 	PHA0 		% -
AT	676 	PHA180 		% +++
AT	892 	PHA0 		% ---
AT	1108 	PHA180 		% + +
AT	1252	RFOFF,PHA0,BEAMOFF
AT	1337	RXPOFF
AT	1387	LOPOFF
%%%% SIGNAL RECEPTION
AT	1919	CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT	3334 	BRX4,BRX5OFF 		% ++
AT	3478 	BRX5 		% ---
AT	3694 	BRX5OFF 		% ++
AT	3838 	BRX5 		% -
AT	3910 	BRX5OFF 		% +++
AT	4126 	BRX5 		% ---
AT	4342 	BRX5OFF 		% + +
AT	4486	BRX4OFF,BRX5
%% test tranmission block stop here
AT	15023	CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%%  GAINCHANNEL SAMPLES ON CH2
AT	15054	CALON
AT	15084	CH1,CH2,CH4,CH5
AT	15588	CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT	15594	BUFLIP
AT	15595	STC
SETTCR	0
AT	998400	REP