tau1-v.tlan
%%%%%%%%%%%%%%%%%%%%
%% IPP 1 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 0
AT 1 CHQPULS,AD1L,AD2R,STFIR
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +++
AT 460 PHA0 % -
AT 532 PHA180 % +
AT 604 PHA0 % -----
AT 964 PHA180 % +++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +++
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -----
AT 4198 BRX5OFF % +++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 1 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 15600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +++
AT 460 PHA0 % -
AT 532 PHA180 % +
AT 604 PHA0 % -----
AT 964 PHA180 % +++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +++
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -----
AT 4198 BRX5OFF % +++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 2 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 31200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++++
AT 460 PHA0 % -
AT 532 PHA180 % +++
AT 748 PHA0 % ----
AT 1036 PHA180 % ++ ++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++++
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +++
AT 3982 BRX5 % ----
AT 4270 BRX5OFF % ++ ++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 2 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 46800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++++
AT 460 PHA0 % -
AT 532 PHA180 % +++
AT 748 PHA0 % ----
AT 1036 PHA180 % ++ ++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++++
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +++
AT 3982 BRX5 % ----
AT 4270 BRX5OFF % ++ ++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 3 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 62400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % ++
AT 460 PHA0 % --
AT 604 PHA180 % +++
AT 820 PHA0 % -
AT 892 PHA180 % ++
AT 1036 PHA0 % -- --
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % ++
AT 3694 BRX5 % --
AT 3838 BRX5OFF % +++
AT 4054 BRX5 % -
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -- --
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 3 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 78000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % ++
AT 460 PHA0 % --
AT 604 PHA180 % +++
AT 820 PHA0 % -
AT 892 PHA180 % ++
AT 1036 PHA0 % -- --
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % ++
AT 3694 BRX5 % --
AT 3838 BRX5OFF % +++
AT 4054 BRX5 % -
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -- --
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 4 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 93600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % ++
AT 460 PHA0 % ----
AT 748 PHA180 % +
AT 820 PHA0 % -
AT 892 PHA180 % +
AT 964 PHA0 % ---
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % ++
AT 3694 BRX5 % ----
AT 3982 BRX5OFF % +
AT 4054 BRX5 % -
AT 4126 BRX5OFF % +
AT 4198 BRX5 % ---
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 4 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 109200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % ++
AT 460 PHA0 % ----
AT 748 PHA180 % +
AT 820 PHA0 % -
AT 892 PHA180 % +
AT 964 PHA0 % ---
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % ++
AT 3694 BRX5 % ----
AT 3982 BRX5OFF % +
AT 4054 BRX5 % -
AT 4126 BRX5OFF % +
AT 4198 BRX5 % ---
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 5 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 124800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % -
AT 388 PHA180 % +
AT 460 PHA0 % ---
AT 676 PHA180 % ++++
AT 964 PHA0 % -
AT 1036 PHA180 % ++ ++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +
AT 3694 BRX5 % ---
AT 3910 BRX5OFF % ++++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % ++ ++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 5 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 140400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % -
AT 388 PHA180 % +
AT 460 PHA0 % ---
AT 676 PHA180 % ++++
AT 964 PHA0 % -
AT 1036 PHA180 % ++ ++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +
AT 3694 BRX5 % ---
AT 3910 BRX5OFF % ++++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % ++ ++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 6 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 156000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % -
AT 388 PHA180 % +
AT 460 PHA0 % --
AT 604 PHA180 % +
AT 676 PHA0 % -
AT 748 PHA180 % ++++++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +
AT 3694 BRX5 % --
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -
AT 3982 BRX5OFF % ++++++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 6 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 171600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % -
AT 388 PHA180 % +
AT 460 PHA0 % --
AT 604 PHA180 % +
AT 676 PHA0 % -
AT 748 PHA180 % ++++++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +
AT 3694 BRX5 % --
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -
AT 3982 BRX5OFF % ++++++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 7 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 187200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ---
AT 388 PHA180 % +
AT 460 PHA0 % -
AT 532 PHA180 % ++
AT 676 PHA0 % --
AT 820 PHA180 % +
AT 892 PHA0 % ----
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ---
AT 3622 BRX5OFF % +
AT 3694 BRX5 % -
AT 3766 BRX5OFF % ++
AT 3910 BRX5 % --
AT 4054 BRX5OFF % +
AT 4126 BRX5 % ----
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 7 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 202800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ---
AT 388 PHA180 % +
AT 460 PHA0 % -
AT 532 PHA180 % ++
AT 676 PHA0 % --
AT 820 PHA180 % +
AT 892 PHA0 % ----
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ---
AT 3622 BRX5OFF % +
AT 3694 BRX5 % -
AT 3766 BRX5OFF % ++
AT 3910 BRX5 % --
AT 4054 BRX5OFF % +
AT 4126 BRX5 % ----
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 8 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 218400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % --
AT 388 PHA180 % +
AT 460 PHA0 % -
AT 532 PHA180 % +
AT 604 PHA0 % -
AT 676 PHA180 % +
AT 748 PHA0 % -
AT 820 PHA180 % +
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -- --
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % --
AT 3622 BRX5OFF % +
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +
AT 3982 BRX5 % -
AT 4054 BRX5OFF % +
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -- --
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 8 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 234000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % --
AT 388 PHA180 % +
AT 460 PHA0 % -
AT 532 PHA180 % +
AT 604 PHA0 % -
AT 676 PHA180 % +
AT 748 PHA0 % -
AT 820 PHA180 % +
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -- --
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % --
AT 3622 BRX5OFF % +
AT 3694 BRX5 % -
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +
AT 3982 BRX5 % -
AT 4054 BRX5OFF % +
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -- --
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 9 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 249600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++
AT 388 PHA0 % -----
AT 748 PHA180 % ++
AT 892 PHA0 % ---- ----
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++
AT 3622 BRX5 % -----
AT 3982 BRX5OFF % ++
AT 4126 BRX5 % ---- ----
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 9 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 265200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++
AT 388 PHA0 % -----
AT 748 PHA180 % ++
AT 892 PHA0 % ---- ----
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++
AT 3622 BRX5 % -----
AT 3982 BRX5OFF % ++
AT 4126 BRX5 % ---- ----
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 10 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 280800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++
AT 388 PHA0 % ---
AT 604 PHA180 % ++++
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % --
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++
AT 3622 BRX5 % ---
AT 3838 BRX5OFF % ++++
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % --
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 10 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 296400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++
AT 388 PHA0 % ---
AT 604 PHA180 % ++++
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % --
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++
AT 3622 BRX5 % ---
AT 3838 BRX5OFF % ++++
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % --
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 11 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 312000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +
AT 388 PHA0 % --
AT 532 PHA180 % +++
AT 748 PHA0 % -
AT 820 PHA180 % ++
AT 964 PHA0 % -
AT 1036 PHA180 % ++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +
AT 3622 BRX5 % --
AT 3766 BRX5OFF % +++
AT 3982 BRX5 % -
AT 4054 BRX5OFF % ++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % ++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 11 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 327600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +
AT 388 PHA0 % --
AT 532 PHA180 % +++
AT 748 PHA0 % -
AT 820 PHA180 % ++
AT 964 PHA0 % -
AT 1036 PHA180 % ++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +
AT 3622 BRX5 % --
AT 3766 BRX5OFF % +++
AT 3982 BRX5 % -
AT 4054 BRX5OFF % ++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % ++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 12 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 343200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % +
AT 388 PHA0 % --
AT 532 PHA180 % +
AT 604 PHA0 % ---
AT 820 PHA180 % +++++ +++++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % +
AT 3622 BRX5 % --
AT 3766 BRX5OFF % +
AT 3838 BRX5 % ---
AT 4054 BRX5OFF % +++++ +++++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 12 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 358800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % +
AT 388 PHA0 % --
AT 532 PHA180 % +
AT 604 PHA0 % ---
AT 820 PHA180 % +++++ +++++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % +
AT 3622 BRX5 % --
AT 3766 BRX5OFF % +
AT 3838 BRX5 % ---
AT 4054 BRX5OFF % +++++ +++++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 13 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 374400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % ---
AT 532 PHA180 % +
AT 604 PHA0 % -
AT 676 PHA180 % +
AT 748 PHA0 % --
AT 892 PHA180 % ++
AT 1036 PHA0 % --
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % ---
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +
AT 3982 BRX5 % --
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % --
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 13 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 390000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % ---
AT 532 PHA180 % +
AT 604 PHA0 % -
AT 676 PHA180 % +
AT 748 PHA0 % --
AT 892 PHA180 % ++
AT 1036 PHA0 % --
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % ---
AT 3766 BRX5OFF % +
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +
AT 3982 BRX5 % --
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % --
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 14 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 405600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % ---
AT 532 PHA180 % ++
AT 676 PHA0 % ---
AT 892 PHA180 % +
AT 964 PHA0 % --- ---
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % ---
AT 3766 BRX5OFF % ++
AT 3910 BRX5 % ---
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --- ---
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 14 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 421200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % ---
AT 532 PHA180 % ++
AT 676 PHA0 % ---
AT 892 PHA180 % +
AT 964 PHA0 % --- ---
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % ---
AT 3766 BRX5OFF % ++
AT 3910 BRX5 % ---
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --- ---
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 15 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 436800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ------
AT 604 PHA180 % +
AT 676 PHA0 % -
AT 748 PHA180 % +
AT 820 PHA0 % --
AT 964 PHA180 % +++ +++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ------
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -
AT 3982 BRX5OFF % +
AT 4054 BRX5 % --
AT 4198 BRX5OFF % +++ +++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 15 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 452400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ------
AT 604 PHA180 % +
AT 676 PHA0 % -
AT 748 PHA180 % +
AT 820 PHA0 % --
AT 964 PHA180 % +++ +++
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ------
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -
AT 3982 BRX5OFF % +
AT 4054 BRX5 % --
AT 4198 BRX5OFF % +++ +++
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 16 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 468000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % ------
AT 676 PHA180 % ++
AT 820 PHA0 % ---
AT 1036 PHA180 % ++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % ------
AT 3910 BRX5OFF % ++
AT 4054 BRX5 % ---
AT 4270 BRX5OFF % ++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 16 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 483600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % ------
AT 676 PHA180 % ++
AT 820 PHA0 % ---
AT 1036 PHA180 % ++
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % ------
AT 3910 BRX5OFF % ++
AT 4054 BRX5 % ---
AT 4270 BRX5OFF % ++
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 17 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 499200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++++
AT 532 PHA0 % ----
AT 820 PHA180 % +
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++++
AT 3766 BRX5 % ----
AT 4054 BRX5OFF % +
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 17 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 514800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++++
AT 532 PHA0 % ----
AT 820 PHA180 % +
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++++
AT 3766 BRX5 % ----
AT 4054 BRX5OFF % +
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 18 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 530400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++++
AT 532 PHA0 % -
AT 604 PHA180 % ++
AT 748 PHA0 % -
AT 820 PHA180 % +
AT 892 PHA0 % ---
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++++
AT 3766 BRX5 % -
AT 3838 BRX5OFF % ++
AT 3982 BRX5 % -
AT 4054 BRX5OFF % +
AT 4126 BRX5 % ---
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 18 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 546000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++++
AT 532 PHA0 % -
AT 604 PHA180 % ++
AT 748 PHA0 % -
AT 820 PHA180 % +
AT 892 PHA0 % ---
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++++
AT 3766 BRX5 % -
AT 3838 BRX5OFF % ++
AT 3982 BRX5 % -
AT 4054 BRX5OFF % +
AT 4126 BRX5 % ---
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 19 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 561600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +++++++++++
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +++++++++++
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 19 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 577200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +++++++++++
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +++++++++++
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 20 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 592800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % ++++
AT 604 PHA0 % --
AT 748 PHA180 % +++
AT 964 PHA0 % -
AT 1036 PHA180 % +
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % ++++
AT 3838 BRX5 % --
AT 3982 BRX5OFF % +++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % +
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 20 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 608400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % ++++
AT 604 PHA0 % --
AT 748 PHA180 % +++
AT 964 PHA0 % -
AT 1036 PHA180 % +
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % ++++
AT 3838 BRX5 % --
AT 3982 BRX5OFF % +++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % +
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 21 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 624000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % -
AT 388 PHA180 % +++
AT 604 PHA0 % -
AT 676 PHA180 % ++
AT 820 PHA0 % -
AT 892 PHA180 % +
AT 964 PHA0 % --
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +++
AT 3838 BRX5 % -
AT 3910 BRX5OFF % ++
AT 4054 BRX5 % -
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 21 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 639600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % -
AT 388 PHA180 % +++
AT 604 PHA0 % -
AT 676 PHA180 % ++
AT 820 PHA0 % -
AT 892 PHA180 % +
AT 964 PHA0 % --
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % -
AT 3622 BRX5OFF % +++
AT 3838 BRX5 % -
AT 3910 BRX5OFF % ++
AT 4054 BRX5 % -
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 22 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 655200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % -
AT 388 PHA180 % ++++
AT 676 PHA0 % -
AT 748 PHA180 % +
AT 820 PHA0 % -
AT 892 PHA180 % ++
AT 1036 PHA0 % -
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % -
AT 3622 BRX5OFF % ++++
AT 3910 BRX5 % -
AT 3982 BRX5OFF % +
AT 4054 BRX5 % -
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 22 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 670800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % -
AT 388 PHA180 % ++++
AT 676 PHA0 % -
AT 748 PHA180 % +
AT 820 PHA0 % -
AT 892 PHA180 % ++
AT 1036 PHA0 % -
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % -
AT 3622 BRX5OFF % ++++
AT 3910 BRX5 % -
AT 3982 BRX5OFF % +
AT 4054 BRX5 % -
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 23 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 686400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ---
AT 388 PHA180 % ++
AT 532 PHA0 % -
AT 604 PHA180 % +
AT 676 PHA0 % -----
AT 1036 PHA180 % +
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ---
AT 3622 BRX5OFF % ++
AT 3766 BRX5 % -
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -----
AT 4270 BRX5OFF % +
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 23 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 702000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ---
AT 388 PHA180 % ++
AT 532 PHA0 % -
AT 604 PHA180 % +
AT 676 PHA0 % -----
AT 1036 PHA180 % +
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ---
AT 3622 BRX5OFF % ++
AT 3766 BRX5 % -
AT 3838 BRX5OFF % +
AT 3910 BRX5 % -----
AT 4270 BRX5OFF % +
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 24 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 717600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % --
AT 388 PHA180 % ++
AT 532 PHA0 % --
AT 676 PHA180 % +
AT 748 PHA0 % ---
AT 964 PHA180 % ++
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % --
AT 3622 BRX5OFF % ++
AT 3766 BRX5 % --
AT 3910 BRX5OFF % +
AT 3982 BRX5 % ---
AT 4198 BRX5OFF % ++
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 24 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 733200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % --
AT 388 PHA180 % ++
AT 532 PHA0 % --
AT 676 PHA180 % +
AT 748 PHA0 % ---
AT 964 PHA180 % ++
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % --
AT 3622 BRX5OFF % ++
AT 3766 BRX5 % --
AT 3910 BRX5OFF % +
AT 3982 BRX5 % ---
AT 4198 BRX5OFF % ++
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 25 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 748800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++
AT 388 PHA0 % -
AT 460 PHA180 % ++
AT 604 PHA0 % --
AT 748 PHA180 % +
AT 820 PHA0 % ---
AT 1036 PHA180 % +
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++
AT 3622 BRX5 % -
AT 3694 BRX5OFF % ++
AT 3838 BRX5 % --
AT 3982 BRX5OFF % +
AT 4054 BRX5 % ---
AT 4270 BRX5OFF % +
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 25 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 764400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % ++
AT 388 PHA0 % -
AT 460 PHA180 % ++
AT 604 PHA0 % --
AT 748 PHA180 % +
AT 820 PHA0 % ---
AT 1036 PHA180 % +
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % ++
AT 3622 BRX5 % -
AT 3694 BRX5OFF % ++
AT 3838 BRX5 % --
AT 3982 BRX5OFF % +
AT 4054 BRX5 % ---
AT 4270 BRX5OFF % +
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 26 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 780000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++
AT 388 PHA0 % -
AT 460 PHA180 % +++++
AT 820 PHA0 % --
AT 964 PHA180 % ++
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +++++
AT 4054 BRX5 % --
AT 4198 BRX5OFF % ++
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 26 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 795600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++++
AT 388 PHA0 % -
AT 460 PHA180 % +++++
AT 820 PHA0 % --
AT 964 PHA180 % ++
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++++
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +++++
AT 4054 BRX5 % --
AT 4198 BRX5OFF % ++
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 27 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 811200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +
AT 388 PHA0 % -
AT 460 PHA180 % +
AT 532 PHA0 % -
AT 604 PHA180 % ++
AT 748 PHA0 % --
AT 892 PHA180 % +
AT 964 PHA0 % --
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -
AT 3838 BRX5OFF % ++
AT 3982 BRX5 % --
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 27 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 826800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % --
AT 316 PHA180 % +
AT 388 PHA0 % -
AT 460 PHA180 % +
AT 532 PHA0 % -
AT 604 PHA180 % ++
AT 748 PHA0 % --
AT 892 PHA180 % +
AT 964 PHA0 % --
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % --
AT 3550 BRX5OFF % +
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -
AT 3838 BRX5OFF % ++
AT 3982 BRX5 % --
AT 4126 BRX5OFF % +
AT 4198 BRX5 % --
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 28 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 842400
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % +
AT 388 PHA0 % -
AT 460 PHA180 % +
AT 532 PHA0 % -----
AT 892 PHA180 % ++
AT 1036 PHA0 % -
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % +
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -----
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 28 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 858000
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % -
AT 316 PHA180 % +
AT 388 PHA0 % -
AT 460 PHA180 % +
AT 532 PHA0 % -----
AT 892 PHA180 % ++
AT 1036 PHA0 % -
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % -
AT 3550 BRX5OFF % +
AT 3622 BRX5 % -
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -----
AT 4126 BRX5OFF % ++
AT 4270 BRX5 % -
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 29 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 873600
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % --
AT 460 PHA180 % +
AT 532 PHA0 % --
AT 676 PHA180 % +
AT 748 PHA0 % -
AT 820 PHA180 % ++++
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % --
AT 3694 BRX5OFF % +
AT 3766 BRX5 % --
AT 3910 BRX5OFF % +
AT 3982 BRX5 % -
AT 4054 BRX5OFF % ++++
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 29 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 889200
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % -
AT 244 PHA180 % +
AT 316 PHA0 % --
AT 460 PHA180 % +
AT 532 PHA0 % --
AT 676 PHA180 % +
AT 748 PHA0 % -
AT 820 PHA180 % ++++
AT 1108 PHA0 % - -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % -
AT 3478 BRX5OFF % +
AT 3550 BRX5 % --
AT 3694 BRX5OFF % +
AT 3766 BRX5 % --
AT 3910 BRX5OFF % +
AT 3982 BRX5 % -
AT 4054 BRX5OFF % ++++
AT 4342 BRX5 % - -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 30 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 904800
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % --
AT 460 PHA180 % +
AT 532 PHA0 % -
AT 604 PHA180 % +
AT 676 PHA0 % --
AT 820 PHA180 % ++
AT 964 PHA0 % -
AT 1036 PHA180 % +
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % --
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -
AT 3838 BRX5OFF % +
AT 3910 BRX5 % --
AT 4054 BRX5OFF % ++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % +
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 30 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 920400
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +++
AT 316 PHA0 % --
AT 460 PHA180 % +
AT 532 PHA0 % -
AT 604 PHA180 % +
AT 676 PHA0 % --
AT 820 PHA180 % ++
AT 964 PHA0 % -
AT 1036 PHA180 % +
AT 1108 PHA0 % -
AT 1180 PHA180 % +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +++
AT 3550 BRX5 % --
AT 3694 BRX5OFF % +
AT 3766 BRX5 % -
AT 3838 BRX5OFF % +
AT 3910 BRX5 % --
AT 4054 BRX5OFF % ++
AT 4198 BRX5 % -
AT 4270 BRX5OFF % +
AT 4342 BRX5 % -
AT 4414 BRX5OFF % +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 31 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 936000
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ----
AT 460 PHA180 % +++
AT 676 PHA0 % -
AT 748 PHA180 % ++
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ----
AT 3694 BRX5OFF % +++
AT 3910 BRX5 % -
AT 3982 BRX5OFF % ++
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 31 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 951600
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % +
AT 172 PHA0 % ----
AT 460 PHA180 % +++
AT 676 PHA0 % -
AT 748 PHA180 % ++
AT 892 PHA0 % -
AT 964 PHA180 % +
AT 1036 PHA0 % -
AT 1108 PHA180 % +
AT 1180 PHA0 % -
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % +
AT 3406 BRX5 % ----
AT 3694 BRX5OFF % +++
AT 3910 BRX5 % -
AT 3982 BRX5OFF % ++
AT 4126 BRX5 % -
AT 4198 BRX5OFF % +
AT 4270 BRX5 % -
AT 4342 BRX5OFF % +
AT 4414 BRX5 % -
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 32 SUBCYCLE 1
%%%%%%%%%%%%%%%%%%%%
SETTCR 967200
AT 9 NCOSEL1
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F6
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % ---
AT 460 PHA180 % ++
AT 604 PHA0 % -
AT 676 PHA180 % +++
AT 892 PHA0 % ---
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % ---
AT 3694 BRX5OFF % ++
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +++
AT 4126 BRX5 % ---
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
%%%%%%%%%%%%%%%%%%%%
%% IPP 32 SUBCYCLE 2
%%%%%%%%%%%%%%%%%%%%
SETTCR 982800
AT 9 NCOSEL2
AT 10 RXPROT,LOPROT
AT 55 BEAMON,F9
%%%%
%%%% - RF TRANSMISSION -
%%%%
AT 100 RFON,PHA180 % ++
AT 244 PHA0 % ---
AT 460 PHA180 % ++
AT 604 PHA0 % -
AT 676 PHA180 % +++
AT 892 PHA0 % ---
AT 1108 PHA180 % + +
AT 1252 RFOFF,PHA0,BEAMOFF
AT 1337 RXPOFF
AT 1387 LOPOFF
%%%% SIGNAL RECEPTION
AT 1919 CH1,CH2,CH4,CH5
%% The next long block is a replica of the transmitter code
%% used for test purposes
AT 3334 BRX4,BRX5OFF % ++
AT 3478 BRX5 % ---
AT 3694 BRX5OFF % ++
AT 3838 BRX5 % -
AT 3910 BRX5OFF % +++
AT 4126 BRX5 % ---
AT 4342 BRX5OFF % + +
AT 4486 BRX4OFF,BRX5
%% test tranmission block stop here
AT 15023 CH1OFF,CH2OFF,CH4OFF,CH5OFF
%%%% GAINCHANNEL SAMPLES ON CH2
AT 15054 CALON
AT 15084 CH1,CH2,CH4,CH5
AT 15588 CH1OFF,CH2OFF,CH4OFF,CH5OFF,CALOFF
AT 15594 BUFLIP
AT 15595 STC
SETTCR 0
AT 998400 REP